User Guide

PureLight by OriginalOptics

Bracket Installation

Screw Type Bracket
Used when there are two screwholes at the front of the loupes eg Orascoptic TTL loupes.
Please note that if you purchased our TTL loupes with a light, your bracket will be pre-installed.
Picture
1. Remove the faceplate
If there is a faceplate, please remove this to expose the holes at the front of the loupes
Picture
2. Screw in the bracket 
Align the screws with the screwholes and gently tighten using the Allen key provided. 
U Type Bracket
Used for the majority of TTL loupes when no screwholes exist.
Picture
1. Position the bracket
Place the bracket over the central frame of your loupes
Picture
2. Secure the bracket
Using the Allen key provided, gently tighten the central screw until the bracket is secure.
Flip Up Bracket
Used for the majority of flip up loupes.
Picture
1. Position the bracket
Place the bracket over the central bar of your loupes, with the teeth on the bracket facing upwards
Picture
2. Attach the bracket
The bracket will click into place

Getting Started

Picture
1. Charge the battery
Please fully charge your battery prior to use. The power indicator on the front of the battery indicates charge level. Please note that the initial charge can take several hours.
Picture
2. Attach light to bracket
If the light unit is not already attached to the bracket, please use the Allen key provided. When fitting your light, push the screw into the hole without thread - you shouldn't feel any resistance. If there is resistance, remove the screw and push it through from the other side.
Picture
3. Wire management (part 1)
Use the rubber loops provided to hold the wire against the side of the loupes frame. Run the remaining wire down your back, connect it to the battery, and place the battery in your pocket / on your belt.
Picture
3. Wire management (part 2)
Form a loop in the wire, and then attach the clip provided. Most clinicians attach the clip to their collar or the head strap of their loupes.
Picture
5. Select light intensity
Use the adjustment dial to select light intensity. Most clinicians use around 75% intensity. A lower intensity will result in a longer battery life.
Picture
6. Composite filter (if needed)
Attach the orange composite filter provided to prevent premature curing of resin-based dental materials.

Cleaning Instructions

The headlight is manufactured using only high-quality components. This is an optical precision instrument that must be cleaned and handled with the greatest care.

  • Only use a lens cleaner on the LED unit with a microfibre cloth
  • All other components can be cleaned with a disinfectant wipe
  • Do not immerse any components into liquid
  • Do not use an autoclave, chemiclave, glutaraldehyde, iodophor or any other sterilisation method​​

Safety Instructions

  1. Only OriginalOptics power supplies are to be used to power the battery
  2. Do not look directly into the headlight or aim the headlight directly into someone’s eyes
  3. The control unit and the battery must be used exclusively for the purpose described
  4. Under no circumstances should you open the housing of the charger or the control unit. Never take the devices apart or undertake modifications​​
STUDENT LOUPES COMPANY .co.uk
Picture
Picture

PRODUCTS
​

Flip Up Loupes
Custom TTL Loupes
OriginalOptics Light
LumaDent Light
SUPPORT
​

Contact Us
Shipping
Returns
Warranty
Refer

Testimonials
ABOUT
​

About Us
Blog
Privacy Policy

Terms of Service
CONNECT
​

OUR BRAND
​

Picture
Picture
​​© 2021 Student Loupes Company
UK loupes, UK dental loupes, Affordable dental loupes, surgical loupes and magnifying loupes for dentists and students
  • Store
  • Flip-Up Loupes
  • TTL Loupes
  • Loupes Headlight
    • PureLight Loupes Light
    • LumaDent Loupes Light
  • Testimonials
  • Support